| Technical parameters
|
|
| Measurement range | 0-600 needle penetration |
| Time setting | Settable range: 0s to 60s |
| Penetration accuracy | With a needle penetration of 0.01, the measurement accuracy is higher. |
| Weight of weights | 50g, providing standard load weight |
| Standard needle | Needle length: 50±1mm (suitable for needle penetration 0~350)
Weight: 2.5g±0.05g |
| Extended needle | The needle length is 60±1mm (suitable for a needle penetration of 350~500). |
| Sample dish specifications | Small sample dish, inner diameter φ55×35mm (suitable for penetration less than 200).
Large sample dish, 45mm (suitable for penetration 200~350). Special sample dish, φ70×80mm (suitable for penetration 350~500). |
| Constant temperature water bath (optional) | It provides a circulating, constant-temperature fiberglass water bath with a temperature control accuracy of ±0.1℃. |
| power supply | 220V 50Hz |
| Power | 200w |
| External dimensions | 360×460×900mm |
| weight | 15Kg |
Beijing Aerospace Experimental Equipment Technology Co., Ltd. will continue to cooperate with colleagues from all walks of life to continuously contribute high-quality testing equipment to the highway field, help the development of the industry and national construction, and create a better future.